Household Cables

Gemini Household Cables

Gemini Multi CoreCables are ideal for power supply application to electrical and electronic equipments and devices. Gemini Multi Core Cable are used and acclaimed all over india by many OEMs ( original equipments manufactures). Outersheath (Jacket) meterial is specially formulated to provide resistance againest, oil, and moisture and provide mechanical strength with out losing its flexibility.

Construction
  • Conductor : Flexible / Solid / strandard / bare annealed copper
  • Insulation ; PVC/FR PVC /HR PVC/FRLS PVC
  • Inner Sheath : PVC/ FR PVC / FRLS PVC /HRPVC
  • Outer Sheath : PVC/FR PVC //FRLS PVC/TPE
Application

For Panel Wrings, Battery, UPS, Machine Tools / Internal and External industrial wiring

Salient Features
  • Electrolytic Gragde copper, which is purest, form of copper available.
  • Manugfactured on 110% self generated power, to avoid even minutest weak point in insulation, sheating or unenenness in conductor laying.
  • In-house developed and manufactured polymers with the best available, high quality ingredients and plasticizers.
  • Specially Formulated Outersheath polymer for oil and chemical resistance and added flexibility
  • Insulation ; PVC/FR PVC /HR PVC/FRLS PVC
  • Inner Sheath : PVC/ FR PVC / FRLS PVC /HRPVC
  • Outer Sheath : PVC/FR PVC //FRLS PVC/TPE
GEMINI HOUSEHOLD CABLES WITH FLEXIBLE COPPER CONDUCTOR
Nominal Cross Sectional Area of Conductor sq. mm No of strand dia of strand No./ (mm) Insulation Thickness nominal (mm) Approx. Overall Diameter mm Resist ance at 20° max. ohms/km Current Rating (Amp.)
2 core (mm) 3 core (mm) 4 core (mm)
0.50 16/0.2 0.60 6.20 6.60 7.20 39.0 4
0.75 24/0.2 0.60 6.50 6.50 7.6 26.0 7
1.0 14/0.3 0.60 6.90 7.30 8.20 18.1 11
1.5 22/0.3 0.60 7.60 8.20 9.30 12.1 15
2.5 36/0.3 0.70 9.00 9.60 11.5 7.41 20
GEMINI HOUSEHOLD CABLES WITH STRANDED COPPER CONDUCTOR
Nominal Cross Sectional Area of Conductor sq. mm No of strand dia of strand No./ (mm) Insulation Thickness nominal (mm) Approx. Overall Diameter mm Resist ance at 20° max. ohms/km Current Rating (Amp.)
2 core (mm) 3 core (mm) 4 core (mm)
1.0 7/0.43 0.60 8.20 8.20 9.20 18.1 11
1.5 7/0.52 0.60 8.80 9.20 10.00 12.1 15
2.5 7/0.67 0.70 10.50 11.00 12.00 7.41 20
4 7/0.85 0.80 12.00 13.00 14.00 4.61 26
6 7/1.04 0.80 13.00 14.50 15.50 3.08 31
10 7/1.35 1.00 16.50 17.50 19.50 1.83 42
16 7/1.70 1.00 19.00 20.00 22.50 1.15 57
25 7/2.14 1.20 23.00 24.50 27.50

0.727

71
35 7/2.50 1.20 25.50 27.50 30.50 0.524 91
50 19/1.78 1.40 29.50 31.50 35.00 0.387 120